Built to run itself
AquaValid is engineered for one job: delivering lab-grade metal data from harsh industrial water, unattended, around the clock. Here’s what that takes — and what it means you never have to do.

Fully automated, end to end
Every step a lab technician would do, the unit does itself — no grab sampling, no skilled operator on site.
Automated sampling
Draws directly from your stream on a continuous ~10-minute cycle.
Automated measurement
Mixing, priming, and measurement run without intervention, cycle after cycle.
Self-calibrating
Onboard custom calibration standards and deionized water keep readings anchored.
Self-cleaning
Automated flushing and cleaning cycles maintain the sample path.
One reagent
A single plasma conditioner — no per-parameter chemistry cabinet.
What’s left for humans
Honestly: not much.
Scheduled service is performed by 2S Water-trained local service partners, with remote support from 2S Water.
Built for harsh sites
High-TDS, harsh-chemistry water where conventional sensors fail — integrated filtration, field-validated at ~3,100 m altitude and pressure-chamber validated to 4,000 m.
What your site needs to provide
| Requirement | Specification |
|---|---|
| Power | 102–132 VAC or 198–264 VAC (CE-compliant models: 198–264 VAC only), 48–63 Hz, 5A internal breaker |
| Sample flow | 38 L/min (10 GPM) max, ½” fNPT sample IN/OUT connection |
| Sample pressure | max 689 kPa (100 psi) |
| Upstream filtration | minimum 20 µm, bubble-free |
| Operating temperature | 15–35 °C (59–95 °F), non-condensing |
| Pressurized air | min 50 PSI, 5 micron filtration, ¼” NPT connection — required to run |
| Waste & exhaust | liquid waste to a client-supplied container; gaseous exhaust vented to atmosphere or a properly vented location |
| Connectivity | reliable cellular network (hard-wired Ethernet only if pre-approved by 2S Water) |
| Physical | ~140 kg (309 lb) fully assembled; bolted to a flat floor |
Final site requirements are confirmed during the site assessment — every deployment starts with a conversation and a sample of your actual water.
Features FAQ
What does “fully automated” actually include?
Sampling, preparation, measurement, calibration, mixing, priming, flushing, and self-cleaning. The routine human role is a ~15-minute daily check: topping up the reagent and a visual inspection.
How does self-calibration work?
The unit carries its own custom calibration standards and deionized water onboard and recalibrates automatically — keeping readings anchored without a field technician or lab visit.
Does it really use only one reagent?
Yes — a plasma conditioner. There’s no cabinet of test-specific chemistry to stock and swap, unlike colorimetric analyzers that consume a different reagent per parameter.
Tell us about your water
We’ll tell you honestly whether AquaValid can see what you need.
Contact us